| Datum | Kwaliteitsniveau | Totaalkiemgetal (kve/ml) | Pseudomonas aeruginosa (kve/100ml) | CP Stafylokokken (kve/100ml) | Vrije chloor (mg/l) | Gebonden chloor (mg/l) | Oxideerbaarheid (mg O2/l) | pH | Ureum (mg/l) | Chloriden (mg/l) | Temperatuur |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Zeer goed | 0.00 | 0.00 | 0.00 | 1.42 | 0.38 | 1.39 | 7.41 | 0.00 | 560.00 | 28.40 | |
| Zeer goed | 0.00 | 0.00 | 0.00 | 1.56 | 0.50 | 1.57 | 7.28 | 0.30 | 523.00 | 29.10 | |
| Zeer goed | 0.00 | 0.00 | 0.00 | 1.38 | 0.22 | 1.40 | 7.05 | 0.28 | 420.00 | 28.80 | |
| Zeer goed | 0.00 | 0.00 | 0.00 | 1.20 | 0.48 | 1.55 | 7.12 | 0.00 | 335.00 | 31.50 | |
| Zeer goed | 0.00 | 0.00 | 0.00 | 1.12 | 0.32 | 1.85 | 7.17 | 0.73 | 85.00 | 30.40 | |
| Zeer goed | 0.00 | 0.00 | 0.00 | 1.25 | 0.43 | 1.28 | 7.42 | 0.24 | 615.00 | 28.70 |
Desinfectietechniek: zoutelektrolyse
Oppervlakte: 444,00 m²